text-small-threshold
Indicates the threshold for text when the transforms should use the single cell halftones.
GUI label
Halftone threshold for text
Type
Resettable, single-valued
Allowed Values
The value you specify is in the form nnnn.nnnu.
nnnn.nnn is a number that can optionally contain a decimal point.
u is the units in inches (i) or millimeters (m) or points (p). If you do not specify a unit, the default unit is pels. You cannot use a decimal point when the unit is pels or points.
For 240-pel resolution printers, valid values are:
- 120 - 1200 pels
- 0.5 - 5 inches
- 12.7-127 millimeters
- 36-360 points
For 300-pel resolution printers, valid values are:
- 150 - 1500 pels
- 0.5 - 5 inches
- 12.7-127 millimeters
- 36-360 points
For 480-pel resolution printers, valid values are:
- 240 - 2400 pels
- 0.5 - 5 inches
- 12.7-127 millimeters
- 36-360 points
For 600-pel resolution printers, valid values are:
- 300 - 3000 pels
- 0.5 - 5 inches
- 12.7-127 millimeters
- 36-360 points
For 720-pel resolution printers, valid values are:
- 360 - 3600 pels
- 0.5 - 5 inches
- 12.7-127 millimeters
- 36-360 points
For 1200-pel resolution printers, valid values are:
- 600 - 6000 pels
- 0.5 - 5 inches
- 12.7-127 millimeters
- 36-360 points
Default value
None
Usage Guidelines
- Use this attribute to set the single cell threshold for images.
- An out-of-range nonzero value causes an error at rip time, and the job is not processed.
- This only applies to InfoPrint 4100 model printers. If this attribute is set on a different printer model, the job fails at rip time.