y-image-shift-back

Specifies the Y offset, in millimeters, of the logical page origin below the physical page origin on the back side of a double-sided sheet.

GUI label

Move image down on back side (inches) or (mm)

DSS

PSF

Type

Resettable, single-valued, per-document

Allowed Values

You can enter a numeric value from -577.97 to 577.97 mm.

The value you specify is in the form nnnn.nnn, which is a number that can optionally contain a decimal point. Millimeters is the unit of measure for the value you specify.

Default Value

No default value

Usage Guidelines

  • This attribute is not valid for ASCII documents.
  • If you specify a value for the document form-definition attribute, InfoPrint ignores the y-image-shift-back attribute and uses the Y-offset value in the form definition. This attribute overrides the Y-offset value in any other form definition.
  • InfoPrint validates and schedules jobs using this attribute against the y-image-shift-range-supported actual destination attribute.
  • This attribute is ignored if the explicit-page-placement and output-format attributes are specified.