Job stays in Reading barcodes state
Various issues can cause jobs to stay in the Reading barcodes state for longer than
expected.
- Use the Complete barcode step action to see the percent of documents read by the scanner and the number of unread
documents. Close the dialog and then do the action again. If the barcode reader is
still reading barcodes for the job, the number of unread documents should decrease.
If the number does not decrease, note which barcode readers are being used for the
job.
Look in the Barcode readers portlet and make sure that the barcode reader is connected. If the barcode reader is disconnected, select View log on the barcode reader portlet and look at the timestamps for any disconnect messages. If some barcodes were read when the barcode reader was disconnected, scan the documents again.
- Check the barcode format on the barcode reader. If the data is not in the expected
format, the information read from the barcode is written to a file in the
/aiw/aiw1/barcodereader
directory (AIX or Linux) orC:\aiw\aiw1\barcodereader
directory (Windows). The file is namedBarcodeReaderName.unmatched
, where BarcodeReaderName is the name of the barcode reader object that received the unexpected data. Compare the contents of that file with the barcode format that was used to read the barcodes. Correct the barcode format or the method used to create the barcode. - Check the properties on the Verification tab of the Job property notebook. If the Complete step when all barcodes are read property is set to No, the job will not leave the Reading barcodes state until you complete the step using the Complete barcode step action.