When Performing Color Adjustment and Color Verification
- When Color Adjustment is not performed: Perform Color Adjustment.
- When Color Adjustment is performed already (when a profile is created and registered): Perform Color Verification. However, perform Color Adjustment, and then perform Color Verification again, when the result of Color Verification is determined to be NG.
During color verification, the average/maximum delta E values in color deviation are evaluated using the standard and tolerance values of the colors that are specified in the selected print standard. Note that the color chart used in the evaluation is modified for use on the machine and does not guarantee conformance with various certification standards.
Color Chart | Evaluated Item | Print Standard | Tolerance | |
---|---|---|---|---|
JA | JC Digital 2011 Coated, Wedge | Average and Max ΔE00 | Japan Color 2011 Coated | Digital print certification |
US | ISO12647-8 Coated V3 F51 | Average and Max ΔE00 | GRACoL2013 CRPC6 | GRACoL Digital Press Cert |
EU | Verify GRACoL2013, Wedge | Average and Max ΔEab | Fogra51 | ISO 12647-8 |
EU | ISO12647-8:2021 Coated V3 F51 | Average ΔE2000 (without boundary patches)
95 % ΔE2000 (without boundary patches) CMY gray average ΔCh CMY gray maximum ΔCh Paper white ΔE2000 |
Fogra51 | ISO 12647-8 |
US | Simple Gray Scale, Wedge 2013 | K gray average w ΔL
K gray maximum w ΔL CMY gray average w ΔL CMY gray maximum w ΔL CMY gray average w ΔCh CMY gray maximum w ΔCh |
GRACol2013 CRPC6 | G7 Grayscale |
The color deviation and judgment result (OK/NG) displayed in Post-judgment might differ from those when a different colorimeter is used.